1 fundamentals, Overview, Fundamentals – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 446

Touch Probe Cycles: Automatic Tool Measurement
19.1 Fundamentals
19
446
TNC 620 | User's Manual Cycle Programming | 5/2013
19.1
Fundamentals
Overview
When running touch probe cycles, Cycle 8 MIRROR
IMAGE, Cycle 11 SCALING and Cycle 26 AXIS-
SPECIFIC SCALING must not be active.
HEIDENHAIN only gives warranty for the function of
the probing cycles if HEIDENHAIN touch probes are
used.
The TNC and the machine tool must be set up by the
machine tool builder for use of the TT touch probe.
Some cycles and functions may not be provided on
your machine tool. Refer to your machine manual.
In conjunction with the TNC's tool measurement cycles, the tool
touch probe enables you to measure tools automatically. The
compensation values for tool length and radius can be stored in
the central tool file TOOL.T and are accounted for at the end of the
touch probe cycle. The following types of tool measurement are
provided:
Tool measurement while the tool is at standstill
Tool measurement while the tool is rotating
Measurement of individual teeth