DATUM AT CENTER OF 4 HOLES (Cycle 418, DIN/ISO: G418,

software option 17)

15.12

15

TNC 620 | User's Manual Cycle Programming | 5/2013

347

3rd center in 2nd axis Q317 (absolute): center of
the 3rd hole in the minor axis of the working plane.
Input range -99999.9999 to 99999.9999

4th center in 1st axis Q318 (absolute): center of
the 4th hole in the reference axis of the working
plane. Input range -99999.9999 to 99999.9999

4th center in 2nd axis Q319 (absolute): center of
the 4th hole in the minor axis of the working plane.
Input range -99999.9999 to 99999.9999

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Datum number in table Q305: Enter the number
in the datum or preset table in which the TNC is
to save the coordinates of the line intersection. If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is at the intersection
of the connecting lines. Input range 0 to 2999

New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the
TNC should set the calculated intersection of the
connecting lines. Default setting = 0 input range
-99999.9999 to 99999.9999

New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the calculated intersection of the
connecting lines. Default setting = 0 input range
-99999.9999 to 99999.9999

Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:

-1

: Do not use! Is entered by the TNC when old

programs are read in (See "Characteristics common
to all touch probe cycles for datum setting")

0

: Write determined datum in the active datum

table. The reference system is the active workpiece
coordinate system

1

: Write the measured datum into the preset table.

The reference system is the machine coordinate
system (REF system).

Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:

0

: Do not set the datum in the touch probe axis

1

: Set the datum in the touch probe axis

NC blocks

5 TCH PROBE 418 DATUM FROM 4

HOLES

Q268=+20

;1ST CENTER 1ST AXIS

Q269=+25

;1ST CENTER 2ND AXIS

Q270=+150

;2ND CENTER 1ST AXIS

Q271=+25

;2ND CENTER 2ND AXIS

Q316=+150

;3RD CENTER 1ST AXIS

Q317=+85

;3RD CENTER 2ND AXIS

Q318=+22

;4TH CENTER 1ST AXIS

Q319=+80

;4TH CENTER 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q260=+10

;CLEARANCE HEIGHT

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+0

;DATUM