Cycle parameters – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 402
Touch Probe Cycles: Special Functions
17.2
MEASURE (Cycle 3, software option 17)
17
402
TNC 620 | User's Manual Cycle Programming | 5/2013
Cycle parameters
Parameter number for result: Enter the number
of the Q parameter to which you want the TNC
to assign the first measured coordinate (X). The
values Y and Z are in the immediately following Q
parameters. Input range 0 to 1999
Probing axis: Enter the axis in whose direction the
probe is to move and confirm with the ENT key.
Input range: X, Y or Z
Probing angle: Angle, measured from the defined
probing axis in which the touch probe is to move.
Confirm with ENT. Input range -180.0000 to
180.0000
Maximum measuring range: Enter the maximum
distance from the starting point by which the touch
probe is to move. Confirm with ENT. Input range
-99999.9999 to 99999.9999
Feed rate for measurement: Enter the measuring
feed rate in mm/min. Input range 0 to 3000.000
Maximum retraction distance: Traverse path in the
direction opposite the probing direction, after the
stylus was deflected. The TNC returns the touch
probe to a point no farther than the starting point,
so that there can be no collision. Input range 0 to
99999.9999
Reference system? (0=ACTUAL/1=REF): Define
whether the probing direction and measuring result
should reference the current coordinate system
(
ACTUAL, can be shifted or rotated) or the machine
coordinate system (
REF):
0
: Probe in the current system and save the
measuring result to the
ACTUAL system
1
: Probe in the fixed machine REF system and save
the measuring result to the
REF system.
Error mode (0=OFF/1=ON): Specify whether the
TNC is to issue an error message if the stylus
is deflected at cycle start. If you select mode
1,
the TNC saves the value
-1 in the fourth result
parameter and continues the cycle:
0
: Error message output
1
: No error message output
NC blocks
4 TCH PROBE 3.0 MEASURING
5 TCH PROBE 3.1 Q1
6 TCH PROBE 3.2 X ANGLE: +15
7 TCH PROBE 3.3 DIST +10 F100 MB1
REFERENCE SYSTEM:0
8 TCH PROBE 3.4 ERRORMODE1