Cycle run, Please note while programming – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 343
DATUM IN TOUCH PROBE AXIS (Cycle 417, DIN/ISO: G417,
software option 17)
15.11
15
TNC 620 | User's Manual Cycle Programming | 5/2013
343
15.11
DATUM IN TOUCH PROBE AXIS (Cycle
417, DIN/ISO: G417, software option
17)
Cycle run
Touch Probe Cycle 417 measures any coordinate in the touch probe
axis and defines it as datum. If desired, the TNC can also enter the
measured coordinate in a datum table or preset table.
1 The TNC positions the touch probe at rapid traverse (value from
FMAX column) following the positioning logic (See "Executing
touch probe cycles", page 280) to the starting point
1
. The TNC
offsets the touch probe by the safety clearance in the positive
direction of the touch probe axis.
2 Then the touch probe moves in its own axis to the coordinate
entered as starting point
1
and measures the actual position
with a simple probing movement.
3 Finally the TNC returns the touch probe to the clearance height
and processes the determined datum depending on the cycle
parameters Q303 and Q305 (See "Characteristics common to all
touch probe cycles for datum setting", page 306) and saves the
actual value in the Q parameters listed below.
Parameter number
Meaning
Q160
Actual value of measured point
Please note while programming:
Danger of collision!
If you set a datum (Q303 = 0) with the touch probe
cycle and also use probe in TS axis (Q381 = 1), then
no coordinate transformation must be active.
Before a cycle definition you must have programmed
a tool call to define the touch probe axis.
The TNC then sets the datum in this axis.