Touch Probe Cycles: Automatic Measurement of Workpiece
Misalignment

14.6 SET BASIC ROTATION (Cycle 404, DIN/ISO: G404, software option

17)

14

298

TNC 620 | User's Manual Cycle Programming | 5/2013

14.6

SET BASIC ROTATION (Cycle 404, DIN/
ISO: G404, software option 17)

Cycle run

With Touch Probe Cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.

NC blocks

5 TCH PROBE 404 BASIC ROTATION

Q307=+0

;PRESET ROT. ANGLE

Cycle parameters

Preset value for rotation angle: Angular value at
which the basic rotation is to be set. Input range
-360.000 to 360.000