beautypg.com

HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual

Page 409

background image

CALIBRATE TS RADIUS INSIDE (Cycle 462, DIN/ISO: G462, software

option 17)

17.7

17

TNC 620 | User's Manual Cycle Programming | 5/2013

409

In order to be able to determine the ball-tip center
misalignment, the TNC needs to be specially
prepared by the machine manufacturer. The machine
manual provides further information.

The characteristic of whether and how your
touch probe can be oriented is already defined in
HEIDENHAIN touch probes. Other touch probes are
configured by the machine tool builder.

RING RADIUS Q407: Diameter of the ring gauge.
Input range 0 to 99.9999

SET-UP CLEARANCE Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP (touch probe table). Input
range 0 to 99999.9999

NO. OF PROBE POINTS Q407 (absolute): Number of
measuring points on the diameter. Input range 0 to
8

REFERENCE ANGLE Q380 (absolute): Angle
between the reference axis of the working plane
and the first touch point. Input range 0 to 360.0000

NC blocks

5 TCH PROBE 462 TS CALIBRATE IN

RING

Q407=+5

;RING RADIUS

Q320=+0

;SET-UP CLEARANCE

Q423=+8

;NO. OF PROBE POINTS

Q380=+0

;REFERENCE ANGLE

This manual is related to the following products: