PRESET COMPENSATION (Cycle 452, DIN/ISO: G452, option) 18.5

18

TNC 620 | User's Manual Cycle Programming | 5/2013

439

Adjustment of interchangeable heads

The goal of this procedure is for the workpiece preset to remain
unchanged after changing rotary axes (head exchange).

In the following example, a fork head is adjusted to the A and C axes.
The A axis is changed, whereas the C axis continues being a part of
the basic configuration.

Insert the interchangeable head that will be used as a reference
head.

Clamp the calibration sphere

Insert the touch probe

Use Cycle 451 to measure the complete kinematics, including the
reference head.

Set the preset (using Q431 = 2 or 3 in Cycle 451) after measuring
the reference head

Measuring a reference head

1 TOOL CALL "TCH PROBE" Z
2 TCH PROBE 451 MEASURE

KINEMATICS

Q406=1

;MODE

Q407=12.5

;SPHERE RADIUS

Q320=0

;SET-UP CLEARANCE

Q408=0

;RETR. HEIGHT

Q253=2000

;F PRE-POSITIONING

Q380=+45

;REFERENCE ANGLE

Q411=-90

;START ANGLE A AXIS

Q412=+90

;END ANGLE A AXIS

Q413=45

;INCID. ANGLE A AXIS

Q414=4

;MEAS. POINTS A AXIS

Q415=-90

;START ANGLE B AXIS

Q416=+90

;END ANGLE B AXIS

Q417=0

;INCID. ANGLE B AXIS

Q418=2

;MEAS. POINTS B AXIS

Q419=+90

;START ANGLE C AXIS

Q420=+270

;END ANGLE C AXIS

Q421=0

;INCID. ANGLE C AXIS

Q422=3

;MEAS. POINTS C AXIS

Q423=4

;NO. OF PROBE POINTS

Q431=3

;PRESET

Q432=0

;BACKLASH, ANG.