beautypg.com

Cycle parameters – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual

Page 293

background image

BASIC ROTATION over two studs (Cycle 402, DIN/ISO: G402,

software option 17)

14.4

14

TNC 620 | User's Manual Cycle Programming | 5/2013

293

Cycle parameters

1st stud: Center in 1st axis Q268 (absolute):
Center of the first stud in the reference axis of
the working plane. Input range -99999.9999 to
99999.9999

1st stud: Center in 2nd axis Q269 (absolute):
Center of the first stud in the minor axis of
the working plane. Input range -99999.9999 to
99999.9999

Diameter of stud 1 Q313: Approximate diameter
of the 1st stud. Enter a value that is more likely
to be too large than too small. Input range 0 to
99999.9999

Measuring height 1 in the probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point in the touch probe axis) at which stud
1 is to be measured. Input range -99999.9999 to
99999.9999

2nd stud: Center in 1st axis Q270 (absolute):
Center of the second stud in the reference axis
of the working plane. Input range -99999.9999 to
99999.9999

2nd stud: Center in 2nd axis Q271 (absolute):
Center of the second stud in the minor axis of
the working plane. Input range -99999.9999 to
99999.9999

Diameter of stud 2 Q314: Approximate diameter
of the 2nd stud. Enter a value that is more likely
to be too large than too small. Input range 0 to
99999.9999

Measuring height of stud 2 in the probe axis
Q315 (absolute): Coordinate of the ball tip center (=
touch point in the touch probe axis) at which stud
2 is to be measured. Input range -99999.9999 to
99999.9999

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

NC blocks

5 TCH PROBE 402 ROT OF 2 STUDS

Q268=-37

;1ST CENTER IN 1ST

AXIS

Q269=+12

;1ST CENTER 2ND AXIS

Q313=60

;DIAMETER OF STUD 1

Q261=-5

;MEASURING HEIGHT 1

Q270=+75

;2ND CENTER 1ST AXIS

Q271=+20

;2ND CENTER 2ND AXIS

Q314=60

;DIAMETER OF STUD 2

Q315=-5

;MEASURING HEIGHT 2

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q307=0

;PRESET ROT. ANGLE

Q305=0

;NO. IN TABLE

Q402=0

;COMPENSATION

Q337=0

;ZERO RESET

This manual is related to the following products: