Cycle run, Please note while programming – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 349
DATUM IN ONE AXIS (Cycle 419, DIN/ISO: G419, software option
17)
15.13
15
TNC 620 | User's Manual Cycle Programming | 5/2013
349
15.13
DATUM IN ONE AXIS (Cycle 419, DIN/
ISO: G419, software option 17)
Cycle run
Touch Probe Cycle 419 measures any coordinate in any axis
and defines it as datum. If desired, the TNC can also enter the
measured coordinate in a datum table or preset table.
1 The TNC positions the touch probe at rapid traverse (value from
FMAX column) following the positioning logic (See "Executing
touch probe cycles", page 280) to the starting point
1
. The TNC
offsets the touch probe by the safety clearance in the direction
opposite the programmed probing direction.
2 Then the touch probe moves to the programmed measuring
height and measures the actual position with a simple probing
movement.
3 Finally the TNC returns the touch probe to the clearance height
and processes the determined datum depending on the cycle
parameters Q303 and Q305. (See "Characteristics common to
all touch probe cycles for datum setting", page 306)
Please note while programming:
Before a cycle definition you must have programmed
a tool call to define the touch probe axis.
If you use Cycle 419 several times in succession to
save the datum in more than one axis in the preset
table, you must activate the preset number last
written to by Cycle 419 after every execution of Cycle
419 (this is not required if you overwrite the active
preset).