beautypg.com

Cycle parameters – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual

Page 325

background image

DATUM FROM INSIDE OF CIRCLE (Cycle 412, DIN/ISO: G412,

software option 17)

15.6

15

TNC 620 | User's Manual Cycle Programming | 5/2013

325

Cycle parameters

Center in 1st axis Q321 (absolute): Center of the
pocket in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999

Center in 2nd axis Q322 (absolute): Center of the
pocket in the minor axis of the working plane. If
you program Q322 = 0, the TNC aligns the hole
center to the positive Y axis. If you program Q322
not equal to 0, then the TNC aligns the hole center
to the nominal position. Input range -99999.9999 to
99999.9999

Nominal diameter Q262: Approximate diameter
of the circular pocket (or hole). Enter a value that
is more likely to be too small than too large. Input
range 0 to 99999.9999

Starting angle Q325 (absolute): Angle between the
reference axis of the working plane and the first
touch point. Input range -360.000 to 360.000

Stepping angle Q247 (incremental): Angle between
two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(negative = clockwise) in which the touch probe
moves to the next measuring point. If you wish to
probe a circular arc instead of a complete circle,
then program the stepping angle to be less than
90°. Input range -120.000 to 120.000

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Datum number in table Q305: Enter the number in
the datum/preset table in which the TNC is to save
the coordinates of the pocket center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is at the center of the pocket.
Input range 0 to 2999

NC blocks

5 TCH PROBE 412 DATUM INSIDE

CIRCLE

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q423=4

;NO. OF PROBE POINTS

Q365=1

;TYPE OF TRAVERSE

This manual is related to the following products: