DATUM CIRCLE CENTER (Cycle 416, DIN/ISO: G416, software

option 17)

15.10

15

TNC 620 | User's Manual Cycle Programming | 5/2013

341

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Datum number in table Q305: Enter the number
in the datum or preset table in which the TNC is to
save the coordinates of the bolt-hole circle center. If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is on the bolt hole
center. Input range 0 to 2999

New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the bolt-hole center. Default setting = 0
input range -99999.9999 to 99999.9999

New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the bolt-hole center. Default setting = 0
input range -99999.9999 to 99999.9999

Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:

-1

: Do not use! Is entered by the TNC when old

programs are read in (See "Characteristics common
to all touch probe cycles for datum setting")

0

: Write determined datum in the active datum

table. The reference system is the active workpiece
coordinate system

1

: Write the measured datum into the preset table.

The reference system is the machine coordinate
system (REF system).

Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:

0

: Do not set the datum in the touch probe axis

1

: Set the datum in the touch probe axis

Probe TS axis: Coord. 1st axis Q382 (absolute):
Coordinate of the probe point in the reference axis
of the working plane at which point the datum is
to be set in the touch probe axis. Only effective if
Q381 = 1st input range -99999.9999 to 99999.9999

Probe TS axis: Coord. 2nd axis Q383 (absolute):
Coordinate of the probe point in the minor axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999

NC blocks

5 TCH PROBE 416 DATUM CIRCLE

CENTER

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q262=90

;NOMINAL DIAMETER

Q291=+34

;ANGLE OF 1ST HOLE

Q292=+70

;ANGLE OF 2ND HOLE

Q293=+210

;ANGLE OF 3RD HOLE

Q261=-5

;MEASURING HEIGHT

Q260=+20

;CLEARANCE HEIGHT

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q320=0

;SET-UP CLEARANCE