Cycle parameters – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 296
Touch Probe Cycles: Automatic Measurement of Workpiece
Misalignment
14.5 BASIC ROTATION compensation via rotary axis (Cycle 403, DIN/
ISO: G403, software option 17)
14
296
TNC 620 | User's Manual Cycle Programming | 5/2013
Cycle parameters
1st meas. point 1st axis Q263 (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
1st meas. point 2nd axis Q264 (absolute):
Coordinate of the first touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
2nd meas. point 1st axis Q265 (absolute):
Coordinate of the second touch point in the
reference axis of the working plane. Input range
-99999.9999 to 99999.9999
2nd meas. point 2nd axis Q266 (absolute):
Coordinate of the second touch point in the minor
axis of the working plane. Input range -99999.9999
to 99999.9999
Measuring axis (1...3: 1 = principal axis) Q272:
Axis in which the measurement is to be made:
1
: Principal axis = measuring axis
2
: Secondary axis = measuring axis
3
: Touch probe axis = measuring axis
Traverse direction 1 Q267: Direction in which the
probe is to approach the workpiece:
-1
: Negative Traverse direction
+1
: Positive traverse direction
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to
SET_UP (touch probe table). Input
range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:
0
: Move at measuring height between measuring
points
1
: Move at clearance height between measuring
points
NC blocks
5 TCH PROBE 403 ROT IN ROTARY AXIS
Q263=+0
;1ST POINT 1ST AXIS
Q264=+0
;1ST POINT 2ND AXIS
Q265=+20
;2ND POINT 1ST AXIS
Q266=+30
;2ND POINT 2ND AXIS
Q272=1
;MEASURING AXIS
Q267=-1
;TRAVERSE DIRECTION
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q312=6
;COMPENSATION AXIS
Q337=0
;ZERO RESET
Q305=1
;NO. IN TABLE
Q303=+1
;MEAS. VALUE
TRANSFER
Q380=+90
;REFERENCE ANGLE