The measured bolt hole center shall be written in the
preset table so that it may be used at a later time.
0 BEGIN PGM CYC416 MM
1 TOOL CALL 69 Z
Call tool 0 to define the touch probe axis
2 TCH PROBE 417 DATUM IN TS AXIS
Cycle definition for datum setting in the touch probe axis
Q263=+7.5
;1ST POINT 1ST AXIS
Touch point: X coordinate
Q264=+7.5
;1ST POINT 2ND AXIS
Touch point: Y coordinate
Q294=+25
;1ST POINT 3RD AXIS
Touch point: Z coordinate
Q320=0
;SET-UP CLEARANCE
Safety clearance in addition to SET_UP column
Q260=+50
;CLEARANCE HEIGHT
Height in the touch probe axis at which the probe can
traverse without collision
Q305=1
;NO. IN TABLE
Write Z coordinate in line 1
Q333=+0
;DATUM
Set touch-probe axis to 0
Q303=+1
;MEAS. VALUE TRANSFER
In the preset table PRESET.PR, save the calculated datum
referenced to the machine-based coordinate system (REF
system)
3 TCH PROBE 416 DATUM CIRCLE CENTER
Q273=+35
;CENTER IN 1ST AXIS
Center of the bolt hole circle: X coordinate
Q274=+35
;CENTER IN 2ND AXIS
Center of the bolt hole circle: Y coordinate
Q262=50
;NOMINAL DIAMETER
Diameter of the bolt hole circle
Q291=+90
;ANGLE OF 1ST HOLE
Polar coordinate angle for 1st hole center
1
Q292=+180
;ANGLE OF 2ND HOLE
Polar coordinate angle for 2nd hole center
2
Q293=+270
;ANGLE OF 3RD HOLE
Polar coordinate angle for 3rd hole center
3
Q261=+15
;MEASURING HEIGHT
Coordinate in the touch probe axis in which the
measurement is made
Q260=+10
;CLEARANCE HEIGHT
Height in the touch probe axis at which the probe can
traverse without collision
Q305=1
;NO. IN TABLE
Enter center of bolt hole circle (X and Y) in line 1
Q331=+0
;DATUM
Q332=+0
;DATUM