HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 330

Touch Probe Cycles: Automatic Datum Setting
15.7 DATUM FROM OUTSIDE OF CIRCLE (Cycle 413, DIN/ISO: G413,
software option 17)
15
330
TNC 620 | User's Manual Cycle Programming | 5/2013
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to
SET_UP (touch probe table). Input
range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:
0
: Move at measuring height between measuring
points
1
: Move at clearance height between measuring
points
Datum number in table Q305: Enter the number
in the datum/preset table in which the TNC is to
save the coordinates of the stud center. If you enter
Q305=0, the TNC automatically sets the display
so that the new datum is on the stud center. Input
range 0 to 2999
New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the stud center. Default setting = 0 input
range -99999.9999 to 99999.9999
New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the stud center. Default setting = 0 input
range -99999.9999 to 99999.9999
Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
-1
: Do not use! Is entered by the TNC when old
programs are read in (See "Characteristics common
to all touch probe cycles for datum setting")
0
: Write determined datum in the active datum
table. The reference system is the active workpiece
coordinate system
1
: Write the measured datum into the preset table.
The reference system is the machine coordinate
system (REF system).
Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0
: Do not set the datum in the touch probe axis
1
: Set the datum in the touch probe axis
NC blocks
5 TCH PROBE 413 DATUM OUTSIDE
CIRCLE
Q321=+50
;CENTER IN 1ST AXIS
Q322=+50
;CENTER IN 2ND AXIS
Q262=75
;NOMINAL DIAMETER
Q325=+0
;STARTING ANGLE
Q247=+60
;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q305=15
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE
TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+1
;DATUM
Q423=4
;NO. OF PROBE POINTS
Q365=1
;TYPE OF TRAVERSE