Touch Probe Cycles: Automatic Datum Setting

15.7 DATUM FROM OUTSIDE OF CIRCLE (Cycle 413, DIN/ISO: G413,

software option 17)

15

330

TNC 620 | User's Manual Cycle Programming | 5/2013

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999

Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999

Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999

Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Datum number in table Q305: Enter the number
in the datum/preset table in which the TNC is to
save the coordinates of the stud center. If you enter
Q305=0, the TNC automatically sets the display
so that the new datum is on the stud center. Input
range 0 to 2999

New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the stud center. Default setting = 0 input
range -99999.9999 to 99999.9999

New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the stud center. Default setting = 0 input
range -99999.9999 to 99999.9999

Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:

-1

: Do not use! Is entered by the TNC when old

programs are read in (See "Characteristics common
to all touch probe cycles for datum setting")

0

: Write determined datum in the active datum

table. The reference system is the active workpiece
coordinate system

1

: Write the measured datum into the preset table.

The reference system is the machine coordinate
system (REF system).

Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:

0

: Do not set the datum in the touch probe axis

1

: Set the datum in the touch probe axis

NC blocks

5 TCH PROBE 413 DATUM OUTSIDE

CIRCLE

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=15

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q423=4

;NO. OF PROBE POINTS

Q365=1

;TYPE OF TRAVERSE