Touch Probe Cycles: Automatic Workpiece Inspection

16.11 MEASURE COORDINATE (Cycle 427, DIN/ISO: G427, software

option 17)

16

388

TNC 620 | User's Manual Cycle Programming | 5/2013

Minimum limit of size Q289: Minimum permissible
measured value. Input range 0 to 99999.9999

PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:

0

: Do not interrupt program run, do not output an

error message

1

: Interrupt program run and output an error

message

Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (See "Tool
monitoring", page 360
). Input range 0 to 32767.9,
alternatively tool name with maximum of 16
characters

0

: Monitoring inactive

>0

: Tool number in the tool table TOOL.T