4 displaying calibration values, Displaying calibration values – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 404

Touch Probe Cycles: Special Functions
17.4
Displaying calibration values
17
404
TNC 620 | User's Manual Cycle Programming | 5/2013
17.4
Displaying calibration values
The TNC saves the effective length and effective radius of the
touch probe in the tool table. The TNC saves the ball-tip center
offset of the touch probe in the touch-probe table in the
CAL_OF1
(principal axis) and
CAL_OF2 (secondary axis) columns. You can
display the values on the screen by pressing the TOUCH PROBE
TABLE soft key.
Make sure that you have activated the correct tool
number before using the touch probe, regardless of
whether you wish to run the touch probe cycle in
automatic mode or manual mode.
For more information about the touch probe table,
refer to the User’s Manual for Cycle Programming.