Cycle run, Please note while programming – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual
Page 386

Touch Probe Cycles: Automatic Workpiece Inspection
16.11 MEASURE COORDINATE (Cycle 427, DIN/ISO: G427, software
option 17)
16
386
TNC 620 | User's Manual Cycle Programming | 5/2013
16.11
MEASURE COORDINATE (Cycle 427,
DIN/ISO: G427, software option 17)
Cycle run
Touch Probe Cycle 427 finds a coordinate in a selectable axis
and saves the value in a system parameter. If you define the
corresponding tolerance values in the cycle, the TNC makes a
nominal-to-actual value comparison and saves the deviation value in
system parameters.
1 The TNC positions the touch probe at rapid traverse (value from
FMAX column) following the positioning logic (See "Executing
touch probe cycles", page 280) to the starting point
1
. The TNC
offsets the touch probe by the safety clearance in the direction
opposite to the defined traverse direction.
2 Then the TNC positions the touch probe to the entered touch
point
1
in the working plane and measures the actual value in
the selected axis.
3 Finally the TNC returns the touch probe to the clearance
height and saves the measured coordinate in the following Q
parameter.
Parameter number
Meaning
Q160
Measured coordinate
Please note while programming:
Before a cycle definition you must have programmed
a tool call to define the touch probe axis.