beautypg.com

Cycle run, Please note while programming – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual

Page 386

background image

Touch Probe Cycles: Automatic Workpiece Inspection

16.11 MEASURE COORDINATE (Cycle 427, DIN/ISO: G427, software

option 17)

16

386

TNC 620 | User's Manual Cycle Programming | 5/2013

16.11

MEASURE COORDINATE (Cycle 427,
DIN/ISO: G427, software option 17)

Cycle run

Touch Probe Cycle 427 finds a coordinate in a selectable axis
and saves the value in a system parameter. If you define the
corresponding tolerance values in the cycle, the TNC makes a
nominal-to-actual value comparison and saves the deviation value in
system parameters.

1 The TNC positions the touch probe at rapid traverse (value from

FMAX column) following the positioning logic (See "Executing
touch probe cycles", page 280) to the st
arting point

1

. The TNC

offsets the touch probe by the safety clearance in the direction
opposite to the defined traverse direction.

2 Then the TNC positions the touch probe to the entered touch

point

1

in the working plane and measures the actual value in

the selected axis.

3 Finally the TNC returns the touch probe to the clearance

height and saves the measured coordinate in the following Q
parameter.

Parameter number

Meaning

Q160

Measured coordinate

Please note while programming:

Before a cycle definition you must have programmed
a tool call to define the touch probe axis.

This manual is related to the following products: