beautypg.com

1 fundamentals, Overview, Fundamentals – HEIDENHAIN TNC 620 (34056x-04) Cycle programming User Manual

Page 284

background image

Touch Probe Cycles: Automatic Measurement of Workpiece
Misalignment

14.1 Fundamentals

14

284

TNC 620 | User's Manual Cycle Programming | 5/2013

14.1

Fundamentals

Overview

When running touch probe cycles, Cycle 8 MIRROR
IMAGE, Cycle 11 SCALING and Cycle 26 AXIS-
SPECIFIC SCALING must not be active.

HEIDENHAIN only gives warranty for the function of
the probing cycles if HEIDENHAIN touch probes are
used.

The TNC must be specially prepared by the machine
tool builder for the use of a 3-D touch probe.

Refer to your machine manual.

The TNC provides five cycles that enable you to measure and
compensate workpiece misalignment. In addition, you can reset a
basic rotation with Cycle 404:

Cycle

Soft key

Page

400 BASIC ROTATION
Automatic measurement using two
points. Compensation via basic
rotation.

286

401 ROT OF 2 HOLES
Automatic measurement using
two holes. Compensation via basic
rotation.

289

402 ROT OF 2 STUDS
Automatic measurement using
two studs. Compensation via basic
rotation.

292

403 ROT IN ROTARY AXIS
Automatic measurement using two
points. Compensation by turning the
table.

295

405 ROT IN C AXIS
Automatic alignment of an angular
offset between a hole center and the
positive Y axis. Compensation via
table rotation.

299

404 SET BASIC ROTATION
Setting any basic rotation.

298