2. Panel Operation

DD35 Production Switcher

2 – 42

Operating Instructions – Rev. 16 / 10.2001

The following parameters are not stored:

D

Key Over

D

Key PVW

D

Cursor/Auto

D

Source Key Bus / Coupl / Split Key (Iso Key)

D

The source of the Mask Bus

Configuration in the Config EBox menu and selection of the function Key Memo
in the Key Main menu.

The key parameters are stored into the key memory,

D

when another key source is selected on the key bus,

D

when the momentarily used key source is selected again on the key bus.

The key parameters of a key source stored in the key memory are called

D

when switch-over is made to this key source on the key bus,

D

when a synthetic key source (Mask Key, Pattern Key) is disabled by pressing
the key once more.

To recall an adjustment already stored for the same source, a synthetic source
(Mask Key, Pattern Key) has to be switched on and switched off with the same sour-
ce.

Note

– If only the key crossbar is switched over with TiM/E Memo

t

, neither a storage

of the former key state nor a call of the new key state is made.

– If the COUPL mode is selected or the key bus is selected as a source, the key

source is automatically selected when selecting the fill signal, thus calling the
stored adjustment of the source signal.

– If the KEY SPLIT (Iso Key) mode is selected, the key source signal can be

selected on the key bus, thus calling the stored adjustment.

– For each input, only one adjustment can be stored. If an input is used for several

keyers in a different way, each procedure described under ”Storing”, effects a
storage into the key memory. The last storage procedure will be the contents
for this input in the key memory.

Condition

Storing into the
key memory

Calling from the
key memory

Restoring from the