3. Menu Operation
DD35 Production Switcher
3 – 144
Operating Instructions – Rev. 16 / 10.2001
3.13.3.2 Function Buttons
Remote P-Bus / Trigger
The Remote / P
S
Bus enables to manually trigger with Trigger the machines de-
fined in the Install / E-Box / P-Bus menu. At present, only 1 trigger can be output
on the P-Bus, which then reaches all machines for which in this case a trigger is
adjusted.
In the 1st line, the trigger number is present (can be used, but must not). In the other
lines, this trigger number is adjusted for the respective machines.
The popup of each machine provides the following selection possibilities:
no Command:
this machine does not get any trigger
default Command:
this machine gets the trigger number
being in the 1st line
all other lines:
here, each trigger is specified with the
name being provided for this machine.
A selection in this area also changes
the general trigger number in the
1st line which then is applicable for all
machines.
It is only possible to trigger those machines which are activated in the Install / P-
Bus menu. The trigger will then be performed by the equal-named button. It then