3. Menu Operation

DD35 Production Switcher

3 – 22

Operating Instructions – Rev. 16 / 10.2001

3.4.4

PANEL LOCKING

To protect the actual control adjustments and settings against unauthorized or acci-
dental changes, the control panel can be locked. This means that (almost) all me-
nus are accessible, but no value in mainframe or panel can be changed. The text
Locked is displayed in all menus. The panel cannot be detached. When the panel
is locked, the attached side panel is also locked.

For locking proceed as follows:

D

Simultaneously press the button TransDur and Store in the master TiM/E
Memo section.

D

Display shows Panel Lock.

D

Using the numeric buttons, enter the password “3511” and press Enter.

For unlocking, repeat the same procedure. With power Off/On the panel can be un-