Rtd module – Basler Electric BE1-11m User Manual
Page 408

396
9424200996 Rev L
Setting
Value
BESTCOMSPlus Screen
Description
Element Mode
Standard
Curve
Protection, Thermal, Thermal
Curve (49TC)
Selects Standard Curve
mode
RTD Biasing
Enabled
Protection, Thermal, Thermal
Curve (49TC)
Enables RTD Biasing
RTD Source
RTD Group 1
Protection, Thermal, Thermal
Curve (49TC)
Selects RTD Group 1
Block
Standard Curve Time
Dial
10
Protection, Thermal, Thermal
Curve (49TC)
Sets Standard Curve
Time Dial to 10
K
0
Protection, Thermal, Thermal
Curve (49TC)
Sets K to 0
Overload
1
Protection, Thermal, Thermal
Curve (49TC)
Sets Overload pickup to
1
Max Emergency
Thermal Capacity
0
Protection, Thermal, Thermal
Curve (49TC)
Sets Max Emergency
Thermal Capacity to 0%
Running Cool Time
Constant
1
Protection, Thermal, Thermal
Curve (49TC)
Sets Running Cool Time
Constant to 1 minute
Stopped Cool Time
Constant
1
Protection, Thermal, Thermal
Curve (49TC)
Sets Stopped Cool Time
Constant to 1 minute
Hot Safe Stall Time
1
Protection, Thermal, Thermal
Curve (49TC)
Sets Hot Safe Stall Time
to 1 second
Cold Safe Stall Time
1
Protection, Thermal, Thermal
Curve (49TC)
Sets Cold Safe Stall Time
to 1 second
49TC
Enabled
Target Configuration, Targets
Enables 49TC target
Step 18: Use BESTCOMSPlus to configure the BESTlogicPlus Programmable Logic shown in Figure
Step 19: Connect a variable resistor and set its value to 120
Ω or connect a fixed 120 Ω resistor to the
RTD1 input on the remote module in three-wire configuration as shown in Figure 269.
Figure 269. RTD1, 3-Wire Connection
Step 20: Navigate to Metering, Motor, RTD Meter on the front-panel display and verify that RTD 1-1 is
approximately 51
°C. This value may be slightly higher or lower depending on the tolerance of
the 120
Ω resistor. The value of RTD 1-1 changes according to the value of the resistor. The
RTD Bias Curve graph in BESTCOMSPlus is used to determine the starting %TC. It is
determined that the starting %TC is 13% for an RTD 1-1 value of 51
°C.
RTD1+
RTD1–
RTD1C
RTD Module
P
0
0
6
1
-4
1
RED
BLACK
BLACK
Thermal Curve (49TC) Test
BE1-11m