background image

FRU Installation

AXP 1410 Installation and Use (6806800H70L)

94

4.2.3

Removing the Board

This section describes how to remove the board from an AdvancedTCA system.

Removal Procedure

The following procedure describes how to remove the board from a system. It assumes that
the system is powered. If the system is unpowered, you can disregards the blue LED and thus
skip the respective step. In that case it is a purely mechanical procedure.

1. Put on an ESD wrist strap.

2. Connect the strap to the shelf by attaching the front or rear ESD jack.

3. Unlatch the ejector handle by lifting up the center sliding portion of the handle,

then rotate the handle slightly (about 15 degrees).
The blue LED blinks indicating that the module power down process is ongoing.

4. Wait until the blue LED is illuminated permanently.

5. Press the handle down to its fully-open position (about 90 degrees).

The board should start to move out of the chassis. Do not force it. If the SAM does
not move, it means the captive screw is not fully unscrewed. Unscrew until loose
and rotate the ejector handle down.

6. Remove the module from the shelf.

Data Loss
Removing the board with the blue LED still blinking causes data loss.
Wait until the blue LED is permanently illuminated, before removing the board.