beautypg.com

3 fan speed sensors, Table 7-12, Sensor no. 8 fan 1 – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 155: Fru information and sensor data records

background image

FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

155

7.2.2.3

Fan Speed Sensors

The following sensors measure the speed of the fans of the FTM.

Table 7-12 Sensor No. 8 Fan 1

Feature

Raw Value/Description

Interpreted Value

Sensor Name

Fan 1

Device

Sensor Type

0x04

Fan

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x1D

Cooling Unit

Entity Instance

0x63

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3F3F

Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable

Reading Type

Unsigned

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0x24, 0x24, 0x24

(1224, 1228, 1224) RPM

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xCE, 0xE6, 0xF2

(7004, 7820, 8228) RPM

This manual is related to the following products: