beautypg.com

Table 7-42, Sensor no. 14, 48.0v feed_2, Fru information and sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 180

background image

FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

180

Table 7-42 Sensor No. 14, 48.0V FEED_2

Feature

Raw Value/Description

Interpreted Value

Sensor Name

48.0V FEED_2

Device

Sensor Type

0x02

Voltage

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x0A

Power Supply

Entity Instance

0x60

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3F3F

Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable

Reading Type

Unsigned

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0x84, 0x77, 0x71

(42.24, 38.08, 36.16) Volts

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xE1, 0xEB, 0xEE

(72, 75.20, 76.16) Volts

This manual is related to the following products: