beautypg.com

2 ipmb link sensor, Table 7-47, Sensor no. 1, ipmb physical – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 184: Ipmb link sensor, Fru information and sensor data records

background image

FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

184

7.3.6.2

IPMB Link Sensor

The following table describes the IPMB link sensor on the PEMs.

Hysteresis support

Threshold access support

Event Message Control

Entire Sensor Only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

Reading Type

According to PICMG 3.0

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0x84, 0x77, 0x71

(42.24, 38.08, 36.16) Volts

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xE1, 0xEB, 0xEE

(72, 75.20, 76.16) Volts

Table 7-46 Sensor No. 0, Hot Swap (continued)

Feature

Raw Value/Description

Interpreted Value

Table 7-47 Sensor No. 1, IPMB Physical

Feature

Raw Value/Description

Interpreted Value

Sensor Name

IPMB Physical

Type of Measurement

IPMB Link State

Class

0x6F

Discrete

Event/Reading Type

0x6F

Sensor-specific

Sensor Type

0xF1

IPMB Link

Sensor Owner LUN

0x00

Entity ID

0x0A

Entity Instance

0x60

Rearm Mode

Auto

Hysteresis support