1 removing the upper ftm, Figure 4-3, Upper rear ftm ejector handles and leds – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 103

FRU Installation
AXP 1410 Installation and Use (6806800H70L)
103
4.4.1
Removing the Upper FTM
Removal Procedure
Follow these steps and refer to the figures to remove the upper fan tray module from the shelf.
1. Loosen the retention screw to the chassis
2. Pull the ejector handle outward to a slightly open position to disengage the hot
swap switch.
Watch for the blue LED to blink. When the blinking stops and the LED remains a
solid blue, the FTM is ready to be removed.
3. Open the ejector handle to a full open position.
4. Using the handle on the front of the FTM, slowly pull the FTM out of the shelf, while
supporting the bottom of the module with the palm of your hand.
Figure 4-3
Upper Rear FTM Ejector Handles and LEDs
The module is heavy; hold it securely.