Power Entry Module Sensor Data Records

This section describes in detail all available IPMI sensors of the Power Entry Module.

7.3.1

PEM FRU Information

There are two PEMs; one at IPMB address 0x66 and another at IPMB address 0x68. The main
FRU (FRU 0) contains the FRU information of the PEM and it is the same for both PEMs (except
for the serial number). FRU 1 contains the FRU information that the active SAM caches as FRU
254 of IPMB address 0x20.

The FRU 0 information in a PEM4000 is represented in the next table.

Pigeon Point Shelf Manager Command Line Interpreter

66: FRU # 0, FRU Info

Common Header: Format Version = 1

Board Info Area:

Version = 1

Language Code = 25

Mfg Date/Time = Jun 1 00:00:00 2005 (4952160 minutes

since 1996)

Board Manufacturer = Network Power, Embedded Computing

Assertion Event Mask (bytes
15,16)

0x02, 0x00

Deassertion Event Mask (bytes
17,18)

0x02, 0x00

Discrete Reading Mask (bytes
19, 20)

0x03, 0x00

Supports 2 States

Reading Definition

Assertion signals a fuse failure

Table 7-34 Sensor No. 29 FuseFail 48VB2 (continued)

Feature

Raw Value/Description

Interpreted Value