beautypg.com

Fru information and sensor data records, 1 introduction, 2 fan tray module sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 145: 1 fan tray module sensor overview, Table 7-1, Ipmi sensors on the fan tray module, Lists fr, Tm in, Fru information, And sensor data records

background image

Chapter 7

AXP 1410 Installation and Use (6806800H70L)

145

FRU Information and Sensor Data Records

7.1

Introduction

This chapter introduces FRU information, e-keying, sensor overviews, and power configuration
data for PEMs and upper and lower fan tray module of the AXP 1410 system. Information in this
chapter includes:

Fan Tray Module Sensor Data Records

Power Entry Module Sensor Data Records

7.2

Fan Tray Module Sensor Data Records

This section describes in detail all available IPMI sensors of the Fan Tray Module.

7.2.1

Fan Tray Module Sensor Overview

The following table lists all IPMI sensors available on the Fan Tray Module.

Table 7-1 IPMI Sensors on the Fan Tray Module

Sensor
No.

Sensor Name

Type of
Measurement

What does it measure?

Sensor Type Availability

0

Hot Swap

Status

State of FRU

Discrete

Always

1

Version Change

Version change

OEM Version Use

Discrete

Always

2

IPMB Link

State of IPMB link

Discrete

Always

3

+12V A_MON

Voltage

Fan 12V source A

Threshold

Always

4

+12V B_MON

Voltage

Fan 12V source B

Threshold

Always

5

+3.3V

Voltage

3.3V output

Threshold

Always

6

+5V A_MON

Voltage

5V source A

Threshold

Always

7

+5V B_MON

Voltage

5V source B

Threshold

Always

8

Fan 1

Fan

Fan Unit 1 Inlet Fan RPM

Threshold

Always

9

Fan 2

Fan

Fan Unit 2 Inlet Fan RPM

Threshold

Always

10

Fan 3

Fan

Fan Unit 3 Inlet Fan RPM

Threshold

Always

11

Fan 4

Fan

Fan Unit 4 Inlet Fan RPM

Threshold

Always

This manual is related to the following products: