Table 7-29, Sensor no. 24 fanfault z2f2, Fru information and sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 168

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70L)
168
Assertion Event Mask (bytes
15,16)
0x02, 0x00
Deassertion Event Mask (bytes
17,18)
0x02, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00
Supports 2 States
Reading Definition
Assertion signals a fan controller fault
Table 7-29 Sensor No. 24 FanFault Z2F2
Feature
Raw Value/Description
Interpreted Value
Sensor Name
FanFault Z2F2
Type of Measurement
Class
0x03
Discrete
Sensor Type
0xC0
OEM-reserved
Sensor Owner LUN
0x00
Entity ID
0x0A
Entity Instance
0x60
Rearm mode
Auto
Event message control
Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x02, 0x00
Deassertion Event Mask (bytes
17,18)
0x02, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00
Supports 2 States
Reading Definition
Assertion signals a fan controller fault
Table 7-28 Sensor No. 23 FanFault Z2F1 (continued)
Feature
Raw Value/Description
Interpreted Value