Table 7-38 Sensor No. 3 +12V Measure
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+12V Measure
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD4, 0xCA, 0xC1
(11.024, 10.504, 10.036) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xFA, 0xFF, 0xFF
(13, 13.26, 13.26) Volts
Table 7-39 Sensor No. 4 +5V Measure
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+5V Measure
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply