beautypg.com

Table 7-38, Sensor no. 3 +12v measure, Table 7-39 – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 177: Sensor no. 4 +5v measure, Fru information and sensor data records

background image

FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

177

Table 7-38 Sensor No. 3 +12V Measure

Feature

Raw Value/Description

Interpreted Value

Sensor Name

+12V Measure

Device

Sensor Type

0x02

Voltage

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x0A

Power Supply

Entity Instance

0x60

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3F3F

Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable

Reading Type

Unsigned

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0xD4, 0xCA, 0xC1

(11.024, 10.504, 10.036) Volts

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xFA, 0xFF, 0xFF

(13, 13.26, 13.26) Volts

Table 7-39 Sensor No. 4 +5V Measure

Feature

Raw Value/Description

Interpreted Value

Sensor Name

+5V Measure

Device

Sensor Type

0x02

Voltage

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x0A

Power Supply

This manual is related to the following products: