Table 7-17, Sensor no. 14 fan 1 outlet, Table 7-18 – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 159: Sensor no. 15 fan 2 outlet, Fru information and sensor data records

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70L)
159
Table 7-17 Sensor No. 14 Fan 1 Outlet
Feature
Raw Value/Description
Interpreted Value
Sensor Name
Fan 1 Outlet
Device
Sensor Type
0x04
Fan
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x1D
Cooling Unit
Entity Instance
0x63
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x24, 0x24, 0x24
(902, 902, 902) RPM
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xCE, 0xE6, 0xF2
(5588, 5610, 5610) RPM
Table 7-18 Sensor No. 15 Fan 2 Outlet
Feature
Raw Value/Description
Interpreted Value
Sensor Name
Fan 2 Outlet
Device
Sensor Type
0x04
Fan
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x1D
Cooling Unit