8.3
Shelf Management Controller
The ShMC part is derived from Artesyn Embedded Technologies's IPMC building block and
consists of two coupled microcontrollers:
IPMC Master Controller (IMC) based on an ATmega2560
IPMC Slave Controller (ISC), based on an ATmega168
8.3.1
IPMB0 Interface
IPMB0-A is connected to the I
2
C controller of the IMC, IPMB0-B to the I
2
C controller of the ISC
of the ShMC. Both microcontrollers have their own I
2
C controller and handle message
transmission and reception independently, including bus error handling and bus arbitration.
Received messages sent from both the IMC and the ISC channels are collected by the IMC. The
IMC dispatches messages which have to be sent either to its own I
2
C interface or to the ISC for
transmission.
8.3.2
IPMC Standard Functions
The standard functionality of the Artesyn Embedded Technologies IPMC is available on the
IPMC of the SAM1410. Refer Supported Commands and FRU Information and Sensor Data Records
of SAM1410 Installation and Use manual, for further information.