2 current sensors, Table 7-43, Sensor no. 15 current measure1 – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 181: Table 7-44, Sensor no. 16 current measure2, Fru information and sensor data records

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70L)
181
7.3.5.2
Current Sensors
The following table describes the sensors that measures the +12V current on the PEM.
Table 7-43 Sensor No. 15 Current Measure1
Feature
Raw Value/Description
Interpreted Value
Sensor Name
Current Measure1
Device
Sensor Type
0x03
Current
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838
Upper Non-Critical, Critical and Non-
Recoverable Thresholds are Readable and
Settable
Reading Type
Unsigned
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xB4, 0xB8, 0xBE
(75, 77, 80) Amps
Table 7-44 Sensor No. 16 Current Measure2
Feature
Raw Value/Description
Interpreted Value
Sensor Name
Current Measure2
Device
Sensor Type
0x03
Current
Class
0x01
Threshold
Sensor Owner LUN
0x00