FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

146

12

Fan 5

Fan

Fan Unit 5 Inlet Fan RPM

Threshold

Always

14

Fan 1 Outlet

Fan

Fan Unit 1 Outlet Fan RPM Threshold

Always

15

Fan 2 Outlet

Fan

Fan Unit 2 Outlet Fan RPM Threshold

Always

16

Fan 3 Outlet

Fan

Fan Unit 3 Outlet Fan RPM Threshold

Always

17

Fan 4 Outlet

Fan

Fan Unit 4 Outlet Fan RPM Threshold

Always

18

Fan 5 Outlet

Fan

Fan Unit 5 Outlet Fan RPM Threshold

Always

20

FanFault Z1F1

OEM-reserved

Zone 1 Fan Unit 1
Controller Fault State

Discrete

Always

21

FanFault Z1F2

OEM-reserved

Zone 1 Fan Unit 2
Controller Fault State

Discrete

Always

22

FanFault Z1F3

OEM-reserved

Zone 1 Fan Unit 3
Controller Fault State

Discrete

Always

23

FanFault Z2F1

OEM-reserved

Zone 2 Fan Unit 1
Controller Fault State

Discrete

Always

24

FanFault Z2F2

OEM-reserved

Zone 2 Fan Unit 2
Controller Fault State

Discrete

Always

25

FanFault Z2F3

OEM-reserved

Zone 2 Fan Unit 3
Controller Fault State

Discrete

Always

26

FuseFail 48VA1

OEM-reserved

48V Feed A Zone 1 Fuse
Failure Flag

Discrete

Always

27

FuseFail 48VA2

OEM-reserved

48V Feed A Zone 2 Fuse
Failure Flag

Discrete

Always

28

FuseFail 48VB1

OEM-reserved

48V Feed B Zone 1 Fuse
Failure Flag

Discrete

Always

29

FuseFail 48VB2

OEM-reserved

48V Feed B Zone 2 Fuse
Failure Flag

Discrete

Always

30

FTM Temp 1

Temperature

Fan Tray Module
Temperature Sensor 1

Threshold

Always

Table 7-1 IPMI Sensors on the Fan Tray Module (continued)