Table 7-3, Sensor no. 4 +12v b_mon, Fru information and sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 148

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70L)
148
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDB, 0xDA, 0xD9
(11.8260, 11.7720, 11.7180) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF7, 0xF9, 0xFA
(13.3380, 13.4460, 13.5) Volts
Table 7-3 Sensor No. 4 +12V B_MON
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+12V B_MON
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Table 7-2 Sensor No. 3 +12V A_MON (continued)
Feature
Raw Value/Description
Interpreted Value