beautypg.com

Table 7-3, Sensor no. 4 +12v b_mon, Fru information and sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 148

background image

FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

148

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3F3F

Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable

Reading Type

Unsigned

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0xDB, 0xDA, 0xD9

(11.8260, 11.7720, 11.7180) Volts

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xF7, 0xF9, 0xFA

(13.3380, 13.4460, 13.5) Volts

Table 7-3 Sensor No. 4 +12V B_MON

Feature

Raw Value/Description

Interpreted Value

Sensor Name

+12V B_MON

Device

Sensor Type

0x02

Voltage

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x0A

Power Supply

Entity Instance

0x60

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Table 7-2 Sensor No. 3 +12V A_MON (continued)

Feature

Raw Value/Description

Interpreted Value

This manual is related to the following products: