2 payload hardware, 1 ethernet interfaces – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 192

Shelf Management Alarm Module
AXP 1410 Installation and Use (6806800H70L)
192
Shelf management controller section with
–
IPMB0-A and IPMB0-B interface to the backplane
–
Handle switch and status LED interface to the face plate
Support logic for testing and debugging as well as local and remote programming of all
programmable devices on the board
Power supply
8.2
Payload Hardware
The payload hardware on the shelf manager board is always powered when power supply is
present. During power-on, the ShMC keeps the payload in a reset state.
The following interfaces are available:
Three Ethernet interfaces
Two redundancy interfaces (serial)
Block transfer interface
One diagnostic console interface (serial)
8.2.1
Ethernet Interfaces
The shelf manager board has three Ethernet ports which are available concurrently.
One 10/100 BaseT out-of-band interface is accessible via a RJ45 connector at the face plate
marked with "ETH". Link and activity status LEDs are integrated into the connector.
Two 10 BaseT interfaces are connected to the backplane connector at the pins Eth1-Hub Tx/Rx
and Eth2-Hub Tx/Rx.
They are compliant with the PICMG 3.0 R 1.0 specification (AdvancedTCA) for the base
interface. These ports connect to the base interface of up to two AdvancedTCA switch boards
in the hub slots of an AdvancedTCA shelf.