2 temperature sensors, Table 7-7, Sensor no. 30 ftm temp 1 – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 151: Fru information and sensor data records
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70L)
151
7.2.2.2
Temperature Sensors
The following sensors measure temperatures of the FTM.
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDF, 0xD5, 0xC8
(4.8168, 4.6008, 4.3200) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF1, 0xF6, 0xFA
(5.2056, 5.3136, 5.4) Volts
Table 7-6 Sensor No. 7 +5V B_MON (continued)
Feature
Raw Value/Description
Interpreted Value
Table 7-7 Sensor No. 30 FTM Temp 1
Feature
Raw Value/Description
Interpreted Value
Sensor Name
FTM Temp 1
Device
Sensor Type
0x01
Temperature
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support