Figure 3-1, Rack mounting dimensions, System installation – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 78: Installation in a 23’’ eia rack/cabinet

background image

System Installation

AXP 1410 Installation and Use (6806800H70L)

78

You have to keep the following conditions when installing the system into an at least 600 mm
(23.62 inch) deep rack. The physical dimensions in the figure below are in millimeters. Please
ensure that 60% of the rack's rear is open.

Installation in a 23’’ EIA Rack/Cabinet

Front mounting brackets are required to attach the shelf to an EIA 23" frame.

1. Locate the standard mounting hole and slot locations on the front mounting

flanges on the AXP 1410 shelf.

2. Fasten the mounting brackets to the back side of the front chassis flanges using M6

screws x 12mm at each of the 5 locations.

3. Be sure to mount the shelf with metal screws or bolts that give a good electrical

connection between the screws or bolts and the mounting surface.

Figure 3-1

Rack Mounting Dimensions

13U Shelf Side View

at Back Side
of Rear Door

3mm
to Door

Cabinet

Door

3.5mm

to Door

25mm Thick

Door, 2X

75mm

42mm

550mm Inside, Door to Door

600mm Deep Cabinet

Air Outlet

Air Inlet