FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

182

7.3.5.3

Temperature Sensor

The following tables describe the temperature sensor available on the PEMs.

Entity ID

0x0A

Power Supply

Entity Instance

0x60

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3838

Upper Non-Critical, Critical and Non-
Recoverable Thresholds are Readable and
Settable

Reading Type

Unsigned

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xB4, 0xB8, 0xBE

(75, 77, 80) Amps

Table 7-44 Sensor No. 16 Current Measure2 (continued)

Feature

Raw Value/Description

Interpreted Value

Table 7-45 Sensor No. 12 LM73 Temp

Feature

Raw Value/Description

Interpreted Value

Sensor Name

LM73 Temp

Device

Sensor Type

0x01

Temperature

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x0A

Power Supply

Entity Instance

0x60

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable