beautypg.com

Table 7-41, Sensor no. 13, 48.0v feed_1, Fru information and sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual

Page 179

background image

FRU Information and Sensor Data Records

AXP 1410 Installation and Use (6806800H70L)

179

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3F3F

Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable

Reading Type

Unsigned

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0xD4, 0xCA, 0xC1

(11.024, 10.504, 10.036) Volts

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xFA, 0xFF, 0xFF

(13, 13.26, 13.26) Volts

Table 7-41 Sensor No. 13, 48.0V FEED_1

Feature

Raw Value/Description

Interpreted Value

Sensor Name

48.0V FEED_1

Device

Sensor Type

0x02

Voltage

Class

0x01

Threshold

Sensor Owner LUN

0x00

Entity ID

0x0A

Power Supply

Entity Instance

0x60

Rearm mode

Auto

Hysteresis support

Readable/Settable

Threshold access support

Readable/Settable

Event message control

Entire Sensor only

Readable threshold mask,
Settable threshold mask (bytes
19, 20)

0x3F3F

Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable

Reading Type

Unsigned

Lower Non-Critical, Critical and
Non-Recoverable thresholds

0x84, 0x77, 0x71

(42.24, 38.08, 36.16) Volts

Upper Non-Critical, Critical and
Non-Recoverable thresholds

0xE1, 0xEB, 0xEE

(72, 75.20, 76.16) Volts

Table 7-40 Sensor No. 5 +12V CC (continued)

Feature

Raw Value/Description

Interpreted Value

This manual is related to the following products: