Table 7-41, Sensor no. 13, 48.0v feed_1, Fru information and sensor data records – Artesyn Centellis 4410 (AXP-1410) Installation and Use (July 2014) User Manual
Page 179

FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70L)
179
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD4, 0xCA, 0xC1
(11.024, 10.504, 10.036) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xFA, 0xFF, 0xFF
(13, 13.26, 13.26) Volts
Table 7-41 Sensor No. 13, 48.0V FEED_1
Feature
Raw Value/Description
Interpreted Value
Sensor Name
48.0V FEED_1
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F
Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x84, 0x77, 0x71
(42.24, 38.08, 36.16) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xE1, 0xEB, 0xEE
(72, 75.20, 76.16) Volts
Table 7-40 Sensor No. 5 +12V CC (continued)
Feature
Raw Value/Description
Interpreted Value