beautypg.com

Table 2-1, Environmental requirements, Hardware preparation and installation – Artesyn ATCA-7365 Installation and Use (November 2014) User Manual

Page 51

background image

Hardware Preparation and Installation

ATCA-7365 Installation and Use (6806800K65N)

51

The following table contains the environmental requirements details.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

Normal Operation: +5 °C (41 °F) to +40
°C (104 °F) according to Telcordia GR-
63-CORE (NEBS) and ETSI EN 300 019-
1-3, Class 3.1
Exceptional Operation: -5 °C (23 °F) to
+55 °C (131 °F) according to Telcordia
GR-63-CORE (NEBS)
Note: This exceeds ETSI EN 300 019-1-
3, Class 3.1E requirements (-5°C to
+45°C)

-40 °C (-40 °F) to +70 °C (158 °F) according
to Telcordia GR-63-CORE (NEBS) and ETSI
EN 300 019-1-2, Class 2.3

Note: This exceeds ETSI EN 300 019-1-1,
Class 1.2 requirements (storage from -
25 °C to +55 °C
Note: This may be further limited by
installed accessories.

Temperature
Change

+/- 0.25 °C/min according to Telcordia
GR-63-CORE

+/- 0.25 °C/min

Relative
Humidity

Normal Operation: 5%rH to 85%rh non-
condensing
Exceptional Operation: 5%rH to 90%rh
non-condensing
According to Telcordia GR-63-CORE
(NEBS) and EN 300 019-1-3, Classes 3.1
and 3.1E

5% to 95% non-condensing according to
Telcordia GR-63-CORE (NEBS) and EN 300
019-1-1, Classes 1.2 and 2.3

Vibration

1g from 5 to 200Hz and back to 5Hz at
a rate of 0.25 octave/minute
(according to Telcordia GR-63-core)

5-20 Hz at 0.01 g

2

/Hz (according to

Telcordia GR-63-core and ETSI EN 300
019-2-2)
20-200 Hz at -3 dB/octave Hz (according
to Telcordia GR-63-core and ETSI EN 300
019-2-2)
Random 5-20Hz at 1 m

2

/s

3

Random 20-200Hz at 3 m

2

/s

3

Shock

Half-sine, 11 ms, 30 m/s

2

Blade level packaging
Half-sine, 6 ms at 180 m/s

2

Free Fall

-

1.2 m/ packaged (according to ETSI 300
019-2-2)
100 mm unpackaged (according to
Telcordia GR-63-core)