18 set payload shutdown time-out command, 19 get module state command, Table 8-43 – Artesyn ATCA-7365 Installation and Use (November 2014) User Manual
Page 271: Set payload shutdown time-out command description, Table 8-44, Get module state command description, Ime-out, Supported ipmi commands
Supported IPMI Commands
ATCA-7365 Installation and Use (6806800K65N)
271
8.4.18 Set Payload Shutdown Time-Out Command
The Set Payload Shutdown Time-Out command is defined as follows.
8.4.19 Get Module State Command
The Get Module State command is used to query the state of a module (RTM with site ID1)
using any of the external interfaces.
Table 8-43 Set Payload Shutdown Time-Out Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4:5
Time-Out measured in hundreds of milliseconds, LSB first
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 8-44 Get Module State Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Module Site ID
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00