2 error simulation, Table 4-28, Logged error events – Artesyn ATCA-7365 Installation and Use (November 2014) User Manual
Page 129: Bios
BIOS
ATCA-7365 Installation and Use (6806800K65N)
129
The Runtime Error Logging can be enabled or disabled. If enabled, the PCI Error Logging can be
enabled or disabled separately.
For correctable memory error logging, there are two additional parameters to prevent the
flooding of the event logs. The parameters are:
Error Threshold - Correctable memory errors are logged when the threshold is reached.
The first correctable memory error is always logged.
Error Logging Limit - The number of logged correctable memory errors for a DIMM is
limited. If the last entry in the log is SMBIOS: 'Correctable memory log disabled' and IPMI:
Memory event 'Correctable ECC logging limit reached'. No further correctable errors are
logged for this DIMM.
4.12.2 Error Simulation
For testing purposes, it is possible to inject errors.
In BIOS setup, enable "Inject Errors" in "Event Logs -> SMBIOS Event Log Settings".
Table 4-28 Logged Error Events
Error
SMIBIOS
IPMI
Correctable:
- Correctable ECC Memory Error
Single-bit ECC memory error
Sensor: Memory, Offset 00h
Correctable:
- Memory Error Limit Reached
- Correctable ECC logging limit
reached
Correctable memory log
disabled
Sensor: Memory, Offset 05h
Uncorrectable:
- Uncorrectable ECC Memory
Error
Multi-bit ECC memory error
Sensor: Memory, Offset 01h
PCI PERR
PCI Parity Error
Sensor: Critical Interrupt,
Offset 04h PCI PERR
PCI SERR
PCI System Error
Sensor: Critical Interrupt,
Offset 05h PCI SERR