FRU Information and Sensor Data Records

ATCA-7365 Installation and Use (6806800K65N)

276

9.2

MAC Address Record

The blade provides one OEM FRU record which contains information about on-board MAC
addresses.

The format of the record is described in the following table.

Table 9-2 Artesyn MAC Addresses Record

Offset

Length

Description

0

1

Record Type ID. A value of C0h (OEM)
shall be used for Artesyn OEM records.

1

1

End of List / Version
[7] End of List. Set to 1b for the last record
[6:4] Reserved. Write as 000b.
[3:0] Record format version. Write as 2h.

2

1

Record Length

3

1

Record Checksum (zero checksum)

4

1

Header Checksum (zero checksum)

5

1

LSB of Manufacturer ID. Write as CDh.

6

1

Second Byte of Manufacturer ID. Write as 65h.

7

1

MSB of Manufacturer ID. Write as 00h.

8

1

Artesyn Record ID. 01h for Artesyn MAC Address Record.

9

1

Record Format Version. 00h for this specification.

10

1

Number of MAC Address Descriptors (N).

11

N*7

Artesyn MAC Address Descriptors. Refer to

Table 9-3

for

definitions of Artesyn MAC Address Descriptor.

Table 9-3 Artesyn MAC Address Descriptor

Offset

Length

Description

0

1

Interface Type. Refer to the table below for Interface
Type Assignments.

1

6

MAC Address. First Octet comes first.