beautypg.com

AMETEK ReFlex Programming Manual User Manual

Page 96

background image

ReFlex Power™ Programming Manual

AC Module Remote Programming

92

M380056-03 Rev L

REPLY

DESCRIPTION

Unable to change the Voltage Range -
Hardware Prohibited, or

User tries to change the voltage range
with

SOUR:VOLT:RANGE

Unable to change the Voltage Range
Output Enabled or Aux Relay Closed

Unable to open Module Data file - file
system problem, or

User tries to store the module data
information and calibration files with

CAL:STORE

5 POINT CAL FILE WRITING ERROR,
or

CAL FILE WRITING ERROR

4.4.2

E

RROR

/E

VENT

Q

UEUE

The Error/Event Queue is a FIFO (First-In-First-Out) buffer for storing detected
errors. When the queue is read with the

SYSTem:ERRor?

query, the error that

was detected first will be read first, and the error that was detected last will be
read last. When all errors are read, the message 0, “No error” will be returned.
Up to 10 errors can be stored before overflow would occur. Overflow will result in
error code -350, “Queue overflow” overwriting the last entry. All subsequent
errors will be ignored until the queue is read, and space is again available.