ReFlex Power™ Programming Manual
Load Module Remote Programming
116
M380056-03 Rev L
:VOLTage <1-2>
:MEASure
:OFFSET
:CALCulate
:UNLock
:STORe
:LOCK
5.6.2
CALIBRATION
SCPI
C
OMMAND
R
EFERENCE
Command
Description
CALibrate
CALIBRATION subsystem
:CALPOTS
Calpots
:GAIN
Gain Pot
:START
Start the gain pot calibration
:CURRent
Enter the current value
:CALCulate
Calibrate the gain calpot
:GAIN?
Returns the gain pot
:OFFSet?
Returns the offset
:INITial
Calibration Initialization subsystem
:CURRent?
Get the initial current value
:CURRent
Set the initial current value
:CURRent
:PROTection
Set the initial over current protection value
:PROTection?
Return the initial over current protection value
:POWer
:PROTection
Set the initial maximum power protection value
:PROTection?
Return the initial maximum power protection value
:RESistance
Set the initial resistance value 1.0
Ω
-5.0K
Ω
:RESistance?
Return the initial resistance value
:STATE
1
Set the initial Cold Power up state to On/Off
:STATE?
Return the initial Cold Power up state setting
:UNDERVOLTage