Eib scpi commands – AMETEK ReFlex Programming Manual User Manual
Page 45
Controller Module Remote Programming
ReFlex Power™ Programming Manual
M380056-03 Rev L
41
Response
Definition for all Modules
0x2000000
Failed at 10% Volt setting, only with other bits set
0x4000000
Failed at 90% Volt setting, only with other bits set
0x20000000
The Controller is unable to detect with any other Modules (Chassis faults / Slot
Power?)
0x40000000
Selftest in progress. Only valid via *TST?, non applicable at module level.
0x80000000
Module Clear in progress. Only valid via *TST?, non applicable at module level.
2.10
EIB SCPI COMMANDS
The EIB (Elgar Interface Bus) subsystem is a proprietary set of customized
commands, conforming to SCPI syntax but not defined by the SCPI
Standard.
2.10.1
EIB
SCPI
C
OMMAND
S
UMMARY
EIB
:CONFigure
:DNUMber?
:INFormation
:ALL?
:VERBose?
:LADDress?
2.10.2
EIB
SCPI
C
OMMAND
R
EFERENCE
Command
Description
EIB
EIB subsystem.
:CONFigure
CONFigure sub-commands
:DNUMber?
Returns the number of devices in the system including the
controller.
:INFormation
:ALL?
Returns the model information string of the devices in the
system.
:VERBose?
Returns the model information string of the devices in the
system with the corresponding logical Address.
:LADDress?
Returns the logical Address of the devices in the system; the
first address is that of the controller.