Measure scpi commands – AMETEK ReFlex Programming Manual User Manual

Page 63

background image

DC Module Remote Programming

ReFlex Power™ Programming Manual

M380056-03 Rev L

59

Command

Description

:FIVEPOINT?

Returns 5 pairs of voltage calibration setpoint count and
related voltage values.

:PROTection

:COUNTS

Set Protection value 0-4095

:MODule

:VOLTage?

Returns Module Voltage rating

:CURRent?

Returns Module Current rating

:LOCK

Disables access to the non-volatile memory. Prevents
attempts to store calibration values.

:UNLock

Unlocks the non-volatile memory to store calibration
constants. The access string is “6867”.

:STORe

Stores the calibration constants in non-volatile memory.

:REVERT:FACTory

Restores the original factory calibration, into non-volatile
memory. Wait 30 seconds and then Power cycle.

Note 1: If CAL:INIT:STATe is ‘1’, the module will automatically turn on as if an OUTP:STATe 1

command had been received. This will only occur during initial power up, *RST will only restore

the saved CAL:INIT values. The unit will not automatically turn on, if enabled, after a *RST.

3.7

MEASURE SCPI COMMANDS

3.7.1

MEASURE

SCPI

C

OMMAND

S

UMMARY

MEASure[n]

:CURRent?

:POLARity?

:VOLTage?

:POWer?

3.7.2

MEASURE

SCPI

C

OMMAND

R

EFERENCE

Command

Description

MEASure

Measure subsystem. Module ‘n’.

:CURRent?

Returns the floating point value of the DC output current in amps.
The value will be negative if the polarity relay is in the INV state.

:POLARity?

Returns Polarity Relay setting.

:VOLTage?

Returns the floating point value of the DC output voltage in volts.
The value will be negative if the polarity relay is in the INV state.

:POWer?

Returns the power in Watts that are delivered to the Load.