Controller Module Remote Programming

34

M380056-03 Rev M

The field to the left of the Clear button, now appears white (not grayed out), to
allow SCPI command input.

It may be necessary to change the IP address, due to address conflicts and
other system requirements. (SYSTem:NETwork:IP

).

Figure 2-14. Query IP Address Example

Figure 2-14 displays an example of querying and changing the IP address to
static. Note that the response to the IP address query after the address is
changed, includes the current IP address followed by the new IP address. The
following are commands associated with setting and querying the IP address:

SYSTem:NETwork:IP?

Query to get the IP address from the
ReFlex Power™ system.

SYSTem:NETwork:IP Sets the ReFlex Power™ system IP

address following the format:
NNN.NNN.NNN.NNN

The ReFlex Power™ System will reconfigure its TCP/IP address to the
requested address, after validating that the requested address is valid and
available for use. When the IP address is set, the IP address configuration is
automatically set to static.

The new IP address is reconfigured a few seconds after being validated, all
current TCP/IP connections will be closed, and new connections at the new
address will have to be created to communicate with the ReFlex Power™
System.